11
IN8-KEYPADLL1 02/26/2013
Restoring the Lock to Factory Default Setting
• Remove power (disconnect 9V battery) from Lock
• Press and Hold EMTEK button
• Restore power (reconnect 9V battery) while continuing to hold EMTEK button
• Continue to hold EMTEK button for 3 seconds
• 1 Green LED Flash and 2 short beeps followed by 1 Green LED Flash and 2 short
beeps indicates the lock has been successfully restored
This procedure clears the lock of all users and restores the Programming Code and
2 User Codes shipped with the lock.
Function Indicators
Valid Code • 1 short beep, EMTEK button ashes Green.
Invalid Code/Access Denied* • 1 Red LED ash
• 2 short beeps
Lock-Out Mode Error • 2 short beeps
• 1 short beep per second for duration
Access Accepted • 1 short beep
• 1 Green LED ash
Low Battery • 4 Red LED ashes
• 4 short beeps
Blackout Battery
**
• 1 long Red LED ash
• 4 long beeps
Button Press Accepted • 1 Yellow LED ash
• 1 Short Beep
Outside Thumb Turn Enabled • 2 Green LED ashes
* If 3 consecutive incorrect codes are entered, the lock emits 4 short beeps and a ashing Red EMTEK
button. The lock will not accept additional input for 20 seconds (20 beeps). When the next valid code is
entered the lock will beep quickly 4 times to alert of the incorrect codes.
**
Battery voltage has dropped too low; keypad will be disabled but metal key override will still work.
Keypad Operation - Beeper & LED Indicators
Place Sticker Here
U.S. patent: 8,176,761
International patents pending.