11
IN8-KEYPADLL1 02/26/2013
Restoring the Lock to Factory Default Setting
Remove power (disconnect 9V battery) from Lock
Press and Hold EMTEK button
Restore power (reconnect 9V battery) while continuing to hold EMTEK button
Continue to hold EMTEK button for 3 seconds
1 Green LED Flash and 2 short beeps followed by 1 Green LED Flash and 2 short
beeps indicates the lock has been successfully restored
This procedure clears the lock of all users and restores the Programming Code and
2 User Codes shipped with the lock.
Function Indicators
Valid Code 1 short beep, EMTEK button ashes Green.
Invalid Code/Access Denied* 1 Red LED ash
2 short beeps
Lock-Out Mode Error 2 short beeps
1 short beep per second for duration
Access Accepted 1 short beep
1 Green LED ash
Low Battery 4 Red LED ashes
4 short beeps
Blackout Battery
**
1 long Red LED ash
4 long beeps
Button Press Accepted 1 Yellow LED ash
1 Short Beep
Outside Thumb Turn Enabled 2 Green LED ashes
* If 3 consecutive incorrect codes are entered, the lock emits 4 short beeps and a ashing Red EMTEK
button. The lock will not accept additional input for 20 seconds (20 beeps). When the next valid code is
entered the lock will beep quickly 4 times to alert of the incorrect codes.
**
Battery voltage has dropped too low; keypad will be disabled but metal key override will still work.
Keypad Operation - Beeper & LED Indicators
Place Sticker Here
U.S. patent: 8,176,761
International patents pending.
Seitenansicht 10